Permit: T06CM04850

Parcel: 141314880

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM04850

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/01/2006 FRAMING Approved IVRS - Inspection :*
10/30/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING SIMPSON ST2115 AT GARAGE HEADER PER 13/DT1
2) FIREBLOCK ENTRY WALL
3) STUCCO MESH NOT COMPLETE
4) NEED TO FIRE SEAL 45 DEGREE CLOSET CEILING WALLS
5) SHEAR BLOCKER ON SHEAR GARAGE WALL-WEST SIDE
6) MASTER BATH PEX WATER LINE NEED TO BE 12" FROM LIGHT CAN
7) NEED TO SEAL ALL CRACKS IN FIRE BLOCKING, DBL WALL LIVING ROOM
8) KITCHEN WATER LINES NEED TO BE 12" FROM LIGTH CANS
9) FIRE SEAL AROUND KITCHEN DUCT
10) MIGHT LOOK AT RELOCATING LIGHT IN ATTIC
10/26/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK ALL MECH DUCTS
2) SECURE OVEN DUCT TO ROOF
3) PEX 12" TO LIGHT CANS
4) H.D.'S NOT INSTALLED, NAIL STUDS TO WALL SHEATHING
5) SUPPORT FOR H20 HTR
6) STRAP ALL FAN DUCTS TO ROOF
7) CAN LIGHT AT NICHE?
8) BANG PLATE CONDENSATE
9) REMOVE 2 X 4 AT REAR WALL FOR H.D.
10) CUT NAIL PLATE MARKED