Permit: T06CM04846

Parcel: 10511040D

Inspection Status: Partial Approval

Inspection History: MECHANICAL - FINAL

Permit Number - T06CM04846

Inspection Description - MECHANICAL - FINAL

Inspection Status - Partial Approval

Date Description Inspector Results Comments
09/20/2007 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) REMOVE THE WHITE WIRES FROM CONDENSOR DISCONNECTS REPLACE WITH A BLACK WIRE
2) EXTEND WATER HEATER VENT MIN. 2' ABOVE WALL ON ROOF
3) VENT ON CONDENSATE MUST BE DOWNSTREAM OF THE TRAP
4) PROVIDE MIN. 1" CLEARANCE TO COMBUSTIBLES AROUND ENTIRE WATER HEATER VENT THRU ROOF
09/20/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*