Permit: T06CM04838

Parcel: 10821018X


Addresses:

4291 N CAMPBELL AV


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM04838

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
07/16/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
CLOSED FLANGES OK
ROOF DRAIN MATERIAL ABS IN RETURN AIR/ P
READ AUTHORIZATION TO WRAP PIPE OK
07/09/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
PROVIDE LISTING FOR OFFSET CLOSET FLANGE TO BE USED AS A 3" AND A 4" FLANGE
07/05/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. SCREW FLANGES TO THE FLOOR AS REQUIRED
2. ALL OPEN PIPING TO REMAIN CAPPED
07/03/2007 PLUMBING - INTERMEDIATE Cancelled
05/15/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WEST OF TOILET ROOM #126
N/H MAY NOT BE SUPPORTED BY THE FITTING
NEED TO SEE CLOSET FLANGES
04/30/2007 PLUMBING - INTERMEDIATE Partial Approval OK TO COVER EAST OF TOILET ROOM #126
04/27/2007 PLUMBING - INTERMEDIATE Cancelled IVRS - AP canceled
04/13/2007 PLUMBING - INTERMEDIATE Partial Approval PRE-SLAB PLUMBING OK

AFTER HRS. $108.00 FEE PAID
CHECK #35397
CAYLOR CONST.
04/09/2007 PLUMBING - INTERMEDIATE Partial Approval 1) OK TO COVER ALL AREAS ON THE SECOND FLOOR
04/06/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO POUR EAST HALF
04/04/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
ALL PIPING IS TO BE SUPPORTED AT EACH FLOOR HORIZONTAL PIPING OVERHEAD REQUIRES HANGER
04/02/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SUPPORT VERTICAL PIPE
TEST OK
3/4" TO DISHWASHER OK
03/28/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
INSPECTED PER UNAPPROVED PLAN REVISION
UPSTAIRS TOILET RM, OK.
INSULATE HW AND CW PER SPEC BOOK
AT DISHWASHER 3/4" SPECIFIED FOR HW
AT REAR SINK OFFSET VENT, OR INSTALL CASTIRON IN RETURN AIR PLENUM.
PVC PIPING ALLOWED IN CONCEALED WALLS ONLY SEE SPEC 5.2.4 BUILDING HAS A RETURN AIR PLENUM