Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/24/2007 FRAMING Approved IVRS - Inspection :*
01/18/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FRONT STOOP NOT POURED PROVIDE 2" CLEARANCE BETWEEN STOOP AND STUCCO WEEP SCREED. OK TO STUCCO HOUSE
2) WIRE SHEATHING MUST ENTER GARAGE FRONT LIGHT BY 1/4" MINIMUM
3) PLAN CALLS FOR #1 SHEARWALL IN KITCHEN SHEAR MUST EXTEND FROM BOTTOM TO TOP PLATE. SOFFIT HAS BEEN INSTALLED PREVENTING SHEAR
4) PROVIDE PROOF THAT KITCHEN SOFFIT IS INSULATED ALL SOFFITS NEED INSULATION
5) PROVIDE BLOCKING #4 SHEARWALL AT CEILING
6) INTERIOR BEARING WALL REQUIRES ANCHOR BOLTS AT 48" ON CENTER
01/16/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREBLOCKS THROUGHOUT
2) ABS VENT OUT OF WALL #2
3) SEAL VAPOR BARRIER AROUND VIGAS