Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM04819

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/31/2006 FRAMING Approved IVRS - Inspection :*
10/30/2006 FRAMING Cancelled IVRS - RI canceled
10/30/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED PLANS, PERMITS AND PRIOR INSPECTION NOTES TO DO RE-INSPECTION
10/29/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TIGHTEN ALL RED HEADS
2) COMPLETE INSTALLATION OF RETRO H.D.'S
3) IF KITCHEN ISLAND HAS OVERHANG OVER 6", REMOVE RECEPTACLE
4) NO SUPPLY OR DWV WATER TESTS
5) INSTALL NAILED FHA STRAPS AT OVER BOXES IN TOP PLATES OF EXTERIOR AND BEARING WALLS
6) B-VENT REQUIRES 1" CLEAR TO COMBUSTIBLES
7) COMPLETE COLLARS FOR FURNACE RETURN AND SUPPLYAT FURR DOWN IN GARAGE