Permit: T06CM04783

Parcel: 126133770


Addresses:

4650 E EASTLAND ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/21/2007 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
25 PSI TEST ON PIPING SYSTEM PER PLAN OK
CONTRACTOR CAN TIE IN AND RE-ENERGIZE SYSTEM TO WATER HEATER AFTER THESE ITEMS CORRECTED
1. WATER HEATER & FURNACE TO HAVE SEDIMENT TRAPS AT GAS ENTRY.
2. T&P DRAIN TO GRAVITY DRAIN TO DAYLIGHT
3. DRAFT HOOD FOR WATER HEATER TO BE PROPERLY INSTALLED.
02/23/2007 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
25 PSI TEST FROM METER LOCATION 1" TO 1" STUB UP AT NORTHEAST AND 1/2" AT EAST SIDE OK SHALL SEE CONTINUATION OF COMPLETED PIPING SYSTEM WITH TEST ON ENTIRE SYSTEM TO OK
02/22/2007 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*