Permit: T06CM04779

Parcel: 141314510

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04779

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/12/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/05/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. MISSED NUMEROUS SPOTS ON ROOF MARKED IN BLK.
2. NEED A.B AT BOT. PLATE GARAGE WALL
3. ADD A 3.5'S TO HINGE BRACES 11/S11
4. NAIL ALL DBL. SHEAR END STUDS VERTICALLY AT 24" O.C