Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM04772
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/29/2007 | FRAMING | Approved | IVRS - Inspection :* | |
01/25/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PEX IN GARAGE HALL TO BE 12" FROM LIGHT 2) SUPPORT ALL ABS EVERY 4' 3) DRAIN IN KITCHEN CEILING HAS NEGATIVE PITCH AND IS CRUSHING DUCT 4) NO PRESSURE 5) MORE PITCH REQUIRED ON WATE HEATER B-VENT |
|
01/23/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
01/22/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |