Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM04743

Parcel: 141313820

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04743

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/20/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/15/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 3 PT TRUSSES NOT SHIMMED AND GARAGE TO HOUSE
2) PULL OUT ONE NAIL AT GIRDER ABOVE KITCHEN ISLAND
3) INSTALL STRAPS AT GARAGE FRONT KST 248
4) PANELS NOT NAILED TO ROOF
5) NEED TO TALK TO GARIN REF. U.S. HOMES PLANS
6) MISSING SHEAR NAILING GARAGE NORTH BOTTOM PLATE
12/08/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PANELS TO ROOF NORTH SIDE
2) MISSED 4' OF NAILING S/W CORNER (MARKED)
3) SHIM ALL TRUSSES AT 3 PT BEARING
4) MISSED 3 PT BEARING AT LIVING ROOM DIAGONAL WALL
5) VERIFY ALL NAILS ON LOAD BEARING HANGERS