Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 08/31/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/16/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Please pay refee before next inspection Areas locked-no access Old areas occupied without temp c of o Need roof access to inspect previous items |
|
| 03/26/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BOXES MORE THAN 1/4" FROM BOX TO SURFACE NEEDS AN APPROVED EXTENDER RING 314.20 2) RECEPTACLES TO BE GFCI PROTECTED 210.8 3) USE APPROVED HARDWARE FOR DEVICES NOT DRYWALL SCREWS 4) NEED PLANS FOR WORK DONE TO BATHROOM |
|
| 02/16/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK TCO SUBJECT TO DETERMINATION OF STEVE LONG 1. VDV CABELING ACROSS ROOF TO BE SUPPORT AND RATED SUNLIGHT RESISTANT. |
|
| 02/15/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. UNIT OCCUPIED WITHOUT INSPECTION 2. FINISH ROOF 3. HAVE ELECTRICIAN PRESENT TO OPEN EQUIPMENT |
|
| 02/07/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) ROOF: TIGHTEN LOOSE FITTINGS 2) CORRECTLY IDENTIFY UNDERGROUNDED CONDUCTORS-BOTH ENDS A/C 3) RECEPTACLE COVERS TO WEATHER PROOF WHETHER OR NOT PLUGGED INTO 406.8 4) FINISH PREVIOUS ITEMS |
|
| 02/06/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) MANUFACTURE FIXTURE CLIPS TO BE EFFECTIVE 2) CORRECTLY LABEL CIRCUIT DIRECTORY-ABREVIATIONS NOT ALLOWED 404.8 3) CLEAN EXCESS FOREIGN MATERIAL FROM PANEL 4) PANEL MORE THAN 1/4" FROM BOX SURFACE 5) OUTLET BOXES MORE THAN 1/4" 314.20 6) TRACK LIGHTS AND BOXES TO BE SUPPORTED 1/4' OF TRACK |