Permit: T06CM04683

Parcel: 11202033P


Addresses:

2000 E ROGER RD G


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06CM04683

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/19/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
THIS BUILDING HAS NON-METALLIC INTERIOR WATER PIPING.
1. DOOR LOCKED -- NO ACCESS
REINSPECTED 2:15 PM

PLUMBING FINAL OK
OK FOR C OF O S.T.O.I
09/15/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NO AVB ON HOSE BIBB
2. NO FULL PORT VALVE AT WATER HEATER
3. CONTINUED "NOT READY'S" MAY RESULT IN A REINSPECTION FEE.
4. AT KITCHEN SINK -- MAY NOT INTERMINGLE MATERIAL TYPES I.E ABS AND PVC MUST USE DRAINAGE FITTINGS -
PVC PRESSURE 45 DEG. NOT APPROVED FOR DRAINAGE.
09/08/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
- OK TO COVER WALLS
- FOR FINAL INSPECTION, WH SUPPLY VALVE SHALL BE FULL-PORT,
- SEDIMENT TRAPS REQUIRED ON GAS PIPING
- ALL FIXTURES SHALL BE INSTALLED FOR FINAL INSPECTION
- ALSO, PLEASE PROVIDE A HOSE BIB VACUUM BREAKER ON EXTERIOR HB ASSOCIATED W/THIS UNIT.