Permit: T06CM04664

Parcel: 140552730

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/29/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/28/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO GROUND WIRE
2) MISSING STUD AT NORTH WEST CORNER SHEARWALL
09/27/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER SD2 FRAMING NOTES #9 ALL SHEARWALLS SHALL HAVE DBL 2 X STUDS AT EACH END, EAST ENTRY WALL CORNER NEEDS STUDS
2) GABLE END BRACING-NOT SPECS SD3/8 GARAGE
3) NORTH GABLE END 2ND FLOOR NO LADDER BLOCKS
09/26/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING STRAPS ON GLU-LAM HEADER GARAGE
2) MISSING H.25 CLIPS AT EACH STUD
3) BACK PORCH MISSING A35 CLIPS ON 2 X 6 JOIST