Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO GROUND WIRE 2) MISSING STUD AT NORTH WEST CORNER SHEARWALL |
|
| 09/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PER SD2 FRAMING NOTES #9 ALL SHEARWALLS SHALL HAVE DBL 2 X STUDS AT EACH END, EAST ENTRY WALL CORNER NEEDS STUDS 2) GABLE END BRACING-NOT SPECS SD3/8 GARAGE 3) NORTH GABLE END 2ND FLOOR NO LADDER BLOCKS |
|
| 09/26/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING STRAPS ON GLU-LAM HEADER GARAGE 2) MISSING H.25 CLIPS AT EACH STUD 3) BACK PORCH MISSING A35 CLIPS ON 2 X 6 JOIST |