Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2007 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 06/04/2007 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WORK PROGRESSING ALL NEW DUCTING SHOULD HAVE BEEN PRE-INSULATED AS PER 2003 IECC SECTION 803.2.8 & SECTION 503.3.3.3 |
|
| 05/24/2007 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. SEAL ALL DUCT JOINTS & INSULATE ALL DUCT WITH 1 1/2" FOIL BACK INSULATION. THIS INCLUDES ALL EXISTING DUCTS ALSO. 2. PROVIDE COMBUSTION AIR TO WATER HEATER ROOM & PROVIDE HIGH COMBUSTION AIR TO FURNACE CLOSET. 3. FURNACE VENT CONNECTOR UPSIDE DOWN. PROVIDE A DOUBLE WALL VENT FOR FURNACE. |