Permit: T06CM04661

Parcel: 127022830


Addresses:

5419 E 2ND ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/12/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/05/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1. KITCHEN COUNTERTOP RECEPTACLES TO BE GFCI PROTECTED - 210.8
2. ALL OUTLETS IN DWELLING UNITS TO BE ARC FAULT PROTECTED - 210.12
3. USE LISTED AND APPROVED APPLIANCE PIGTAILS
4. ANTI-TIP DEVICE FOR RANGE NEEDED
5. CLEAN EXCESS FOREIGN MATERIAL FROM PANEL -- 110.12
6. TIGHTEN LOOSE FITTINGS A/C
7. EXPOSED CONDUCTORS PASSING THROUGH WALL
8. CANNOT TRIM CONDUCTORS -- USE APPROVED LUG AND ALL STRANDS
9. INSTALL ALL STRANDS UNDER LUGS
08/31/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
08/27/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*