Permit: T06CM04628

Parcel: 140550520

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/08/2006 BUILDING - FINAL Approved IVRS - Inspection :*
12/06/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 4 AND 5 OF 11/30/06 INSPECTION NOT COMPLIED WITH
11/30/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ACCESS TO A/C CONDENSOR DISCONNECT OBSTRUCTED BY UNIT. MUST HAVE 30" X 30" WORK AREA
2) A/C CONDENSOR NOT LEVEL
3) MAX ALLOWED FUSE/LB FOR CONDENSOR 30A-50A INSTALLED
4) STUCCO WEEP SCREED MUST BE 4" ABOVE SOIL
5) STUCCO WEEP SCREED CANNOT BE COVERED BY CONCRETE MUST HAVE 2" CLEARANCE TO CONCRETE
6) OPEN GROUND BATHROOM GFCI
7) INCANDESCENT LIGHT MUST BE 12" HORIZONTALLY FROM CLOSET SHELF