Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) PATIO COLUMNS STILL NOT PER DRAWINGS |
|
| 09/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 3 KINGS AT GARAGE HDR PER PLAN 2) 2 NAILS REQUIRED INTO BOTTOM PLATE OF EVERY WIND BRACE 3) NAILS OVER SET IN REAR SHEAR NAILS 4) DBL 2 X 8 HDR MISSING AT ENTRY 5) INTERIOR GARAGE SHEAR TRANSFER NOT PER PLAN 6) HINGE BRACING NOT PER PLAN 7) PROVIDE POSITIVE CONNECTION AT PATIO LEDGER 8) PROVIDE CITY APPROVED TRUSS SPECS 9) 8D NAILS 6" ON CENTER REQUIRED INTO BIRD BLOCKS 10) NAIL HINGE BRACE BLOCKS THROUGH ROOF SHEATHING PER PLAN |