Permit: T06CM04622

Parcel: 106121250

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/17/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
CORRECTIONS MADE OK
OK TO COVER UNDERGROUND
OK TO COVER WALLS
WILL NEED TO SEE CLOSET FLANGE AFTER CONCRETE IS RE-POURED.
04/10/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
04/09/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
03/27/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) PIPE DID NOT GET WRAPPED BEFORE CONCRETE WAS POURED
2) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP, TRAP ARM MAY NOT CHANGE SIZE, TRAP AND TRAP ARM TO BE THE SAME SIZE, 1 1/2" TRAP ARM MAY NOT EXCEED 3'-6"
3) NO TEST ON ABS