Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM04602
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/18/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
08/17/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLAN SPEC C1 WASTE & VENT VERTICAL TO HORIZONTAL CHANGE OF DIRECTION SHALL BY WYE PATTERN FITTINGS (SWEEP) SEAL JOINTS IN INSULATION HORIZONTAL C1 PIPE REQUIRES SUPPORT AT EACH END. TWO SUPPORTS PER LENGTH. |