Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/22/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 10/26/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - REMOVE SHEETROCK SCREW IN H2.5 CLIPS AND INSTALL APP. NAILS. - REMOVE SHEETROCK SCREW IN HANGERS JOIST SUPP. AND INSTALL APP. NAILS ACCORDING WITH SPEC. - OPEN ONE SIDE OF FOOTING FOR DEPTH COMPLIANCE - PROVIDE LUG SCREW ON LEDGER ACCORDING WITH APPROVED PLAN. - PROVIDE ACCESSIBILITY PER ROOF INSPECTION |
|
| 09/26/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE APPROVED PLANS/PERMITS 2. YOU CAN'T USE SHEETROCK SCREWS IN CLIPS OR HOLD DOWNS. 3. YOU CAN'T USE ROOFING TACKS FOR PORT BASES OR CAPS. |