Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM04591

Parcel: 129052060


Addresses:

2243 E 18TH ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/22/2007 BUILDING - FINAL Approved IVRS - Inspection :*
10/26/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- REMOVE SHEETROCK SCREW IN H2.5 CLIPS AND INSTALL APP. NAILS.
- REMOVE SHEETROCK SCREW IN HANGERS JOIST SUPP. AND INSTALL APP. NAILS ACCORDING WITH SPEC.
- OPEN ONE SIDE OF FOOTING FOR DEPTH COMPLIANCE
- PROVIDE LUG SCREW ON LEDGER ACCORDING WITH APPROVED PLAN.
- PROVIDE ACCESSIBILITY PER ROOF INSPECTION
09/26/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE APPROVED PLANS/PERMITS
2. YOU CAN'T USE SHEETROCK SCREWS IN CLIPS OR HOLD DOWNS.
3. YOU CAN'T USE ROOFING TACKS FOR PORT BASES OR CAPS.