Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM04585

Parcel: 116276940

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04585

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/01/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/31/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE APPROVED TRUSS SPECS
2) NAIL ALL SHEAR PANELS ACCORDINGLY
3) NAIL ALL LEDGERS ACCORDINGLY
4) THREE ANCHOR BOLTS REQUIRED IN "A" SHEAR PANELS
5) NAIL ROOF SHEATHING TO BIRD BLOCKS
6) NAIL ROOF SHEATHING WHERE MARKED
7) 10D NAILS 6 ON CENTER REQUIRED THRU ROOF SHEATHING INTO LEDGERS
8) WEB STIFFNERS REQUIRED AT INTERIOR BEARING WALLS & H2.5'S
9) STOPPED INSPECTION-HOUSE NOT READY