Permit: T06CM04584

Parcel: 12416093A

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
07/26/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
07/25/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
SMOKE DETECTORS TO CLOSE TO CORNERS
07/24/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK UNIT ON SW SIDE COMPLETE INSTALLATION OF BUSHINGS IN METAL STUDS ON SECOND UNIT.
07/19/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. USE APPROVED BUSHINGS WHEN INSTALLING ROMEX THRU METAL STUDS OR BEAMS PER NEC
2. SUPPORT VERTICAL RUNS IN WALLS, CODE REQUIRES SUPPORT WITHIN 12" AT TERMINATION