Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/19/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEW REVISION CALL FOR (2) 2X4 @ 16" O.C OVER LIVING ROOM ONLY NAIL (2) 2X4 JOISTS TOGETHER W/16d STAGGER @ 12" O.C PROVIDE ATTIC ACCESS 22" X 30" |
|
| 05/08/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE REVISION BY DSD CITY OF TUCSON REGARDING INTERIOR JOIST CHANGE TJI FOR 2X4 @ 16" O.C 2. PROVIDE REVISION OR ACCEPTED LETTER FOR HALLWAY 2'-11' SECTION R311.3 OF IRC CALL FOR MINIMUM WIDTH OF HALLWAY SHALL BE NOT LESS THAN 36" FINISH 3. PROVIDE REVISION FOR CHANGE ON MAIN DOOR PLANS CALL FOR FRENCH DOOR 6" WIDTH INSTEAD 36" WIDTH. |
|
| 04/23/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* METAL BLDG. DOESN'T MATCH ARCH. PLANS |
|
| 04/16/2007 | FRAMING | Partial Approval | IVRS - Inspection :* THIS INSPECTION COVER SHELL BLD. FOR ALL STRUCTURAL MAIN FRAMING |
|
| 04/13/2007 | FRAMING | Partial Approval | IVRS - Inspection :* FRAMING PARTIAL APPROVED MUST PROVIDE CONNECTIONS BETWEEN COLUMNS AND RAFTER APPROVED PLANS AND CALC. CALL FOR 8 #12 SCREW ON CONNECTION ABOVE MENTIONED. |