Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/21/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) RANGE HOME RUN CUT 2) FIREBLOCK DROP CEILINGS 2ND FLOOR 3) APPROVED TO INSULATE |
|
| 02/12/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE WATER TEST DWV SYSTEM OR POTABLE WATER 2) BLOCK MECHANICAL PLENIUM 3) FIRESTOP ELECTRICAL PENETRATION TO UPSTAIRS 4) SECURE ALL ROMEX 8" FROM BOXES 5) ? HOME RUNS 6) NAIL PROTECT ELECTRIC THRU-OUT 7) RELOCATE 220 WIRE UPSTAIRS 8) FIREBLOCK MISSING UPSTAIRS LAUNDRY 9) SECURE 90 VENTS THRU ROOF TOP 10) NAIL PROTECT PEX THRU-OUT 11) REPAIR OVER KNOTCH UPSTAIRS INTERIOR SHEARWALL 12) FIREBLOCK UPSTAIRS MECH DROP 13) REPAIR ALL DAMAGED FIREBLOCK 14) SMOKIES MUST BE MINIMUM 36" FROM REGISTERS 15) SECURE 4 GANG BOXES BOTH ENDS |