Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/30/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/29/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - TUBS TEST OK - YOU HAVE PEX TOUCHING METAL BANG PLATE AT NE LAVITORY, ALSO, SECURE TUBING IN WALL W/CLAMPS. - I WOULD HAVE APPROVED THIS IF YOU HAD PROVIDED A TEST ON NEW WORK. - SWEEPS REQUIRED AT TRAP ARMS - PLEASE RETEST ABS. |
|
| 11/21/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - A 3" CLEANOUT W/A MIN. 2 1/2" CO PLUG IS REQUIRED AT FIRST BATHROOM BECAUSE 3" BRANCH CANNOT BE SERVICED THROUGH TWO WAY C.O - LAVATORY TRAP ARM IS LIMITED TO 1 1/2" AND 42" DEVELOPED LENGTH. - SECURE CLOSET FLANGES PER MANUFACTURERS PRINTED INSTRUCTIONS AS WELL AS UPC 15 #5 - TEST TUBS TO FLOOD LEVEL. |