Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/24/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
08/23/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - YOU HAVE BACK PITCH AT HC WC - TEST CAP IS LEAKING - CALL FOR PRE-SLAB INSP ALSO AFTER CORRECTING - PIPING NOT PER PLAN - PLAN SHOWS EXISTING 4" BUILDING DRAIN W/UPPER TERMINAL C.O. - YOU HAVE NEW 3" ABS INSTALLED W/NO UPPER CO - REDLINE CHANGES ON PLAN AND HAVE PLAN REVISED. |
|
08/22/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* MIKE 409-2568 REQ. AFTERNOON POST ADDRESS |