Permit: T06CM04515

Parcel: 10604256A


Addresses:

344 E NAVAJO RD #01

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/22/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
REVISED SITE UTILITY PLAN ON SITE
OK TO COVER ALL AREAS
11/17/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. SCREW CLOSET FLANGES TO THE FLOOR.
2. TRAP ARM MAY NOT CHANGE SIZE.
3. FILL BATHTUBS ALL THE WAY.
4. SUPPORT VERTICAL ABS.
5. SUPPORT HORIZONTAL ABS.
6. I NEED TO SEE LISTING FOR T&S VALVES.
7. PEX MAY NOT PASS OVER ELECTRIC SERVICE PANEL.