Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM04486
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/16/2006 | FRAMING | Approved | IVRS - Inspection :* | |
11/08/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H2.5 MISSING AT INTERIOR BEARING JOIST TO BEARING PLATE 2) COMPLY WITH DETAIL (A) SHEET 13 3) GARAGE ONLY OK 4) NEED APPROVED DETAIL ON INTERIOR BEARING PLATE |