Permit: T06CM04484

Parcel: 136327300

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
05/16/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
03/30/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) GROUNDING METAL BOXES REQUIRES THE USE OF A GREEN GROUNDING SCREW IN THE HOLE MARKED "GR" IN THE METAL BOX
2) OK TO INSTALL LATHE
03/21/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BOXES FOR FANS MUST BE UL LISTED FOR FANS
2) UNUSED KNOCKOUTS MUST BE FILLED
3) ALL METAL BOXES MUST BE GROUNDED
4) STAPLE WIRES WITHIN 8" OF BOXES
5) OUTER INSULATION OF ROMEX WIRE MUST EXTEND AT LEAST 1/2" INTO BOX