Permit: T06CM04477

Parcel: 110151690


Addresses:

5652 E SILVER ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
08/23/2006 MECHANICAL - FINAL Approved
08/22/2006 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PROVIDE MIN. 1" CLEARANCE AROUND FURNACE VENT FROM COMBUSTIBLES.
- DO NOT USE A TEMPORARY 3-WAY RECEPTACLE FOR PERMANENT PAVED TO FURNACE, PUMP & HUMIDIFIER.
- 60 AMP. FUSES TOO LARGE FOR CONDENSOR.
- DO NOT USE WHITE WIRE FOR CONDUCTORS.
- LOW VOLTAGE WIRE MUST BE PROTECTED FROM DAMAGE.
- SEAL AROUND END VENT WHERE REFE LINES PENETRATE.
- IDENTIFY CIRCUIT BREAKERS FOR FURNACE & A/C