Permit: T06CM04461

Parcel: 116010620

Inspection Status: Partial Approval

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/17/2007 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) NEED TO COVER UNUSED BREAKER WITH PLUG
2) NEED COVERS ON J-BOXES ABOVE SERVICE PANEL
08/10/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL INTERMEDIATES MUST BE APPROVED
2) NEED TO BE 18" IN DEPTH PER PLAN FOR ELECTRIC UNDERGROUND
3) NO ACCESS TO INSPECT
4) ELECTRIC BOX FOR 20 AMP BREAKERS
5) DRAIN LINE NEEDS TO TERMINATE INTO 18" DRYWALL-NOT GROUND WITH A SCREEN
6) 3/4 WATER LINE NEEDS BLUE TRACER WIRE FROM SERVICE TO EDGE UNDER SLAB
08/01/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*