Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/08/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1. ALL GAS PIPING IS EXISTING PRESSURE TEST OK 2. EWC CORRECTION MADE OK 3. PLUMBING FINAL OK 4. OK FOR C OF O S.T.O.I |
|
| 11/06/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 11/02/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. TAILPIECE FOR EWC IS 1 1/4" TRAP AND TRAP ARM TO BE THE SAME SIZE. 2. ALL THAT IS LEFT IS EWC DRAIN. |
|
| 10/30/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. YOU DON'T HAVE 03075 PROGRESS APPROVAL PROVIDE VERIFICATION THAT FLOOR DRAINS HAVE BEEN CORRECTED. 2. HAVE PLUMBER READ ALL ELEVEN PLUMBING NOTES ON P1.1 AND VERIFY COMPLETION. 3. ELECTRIC WATER COOLER REQUIRES DRAINAGE FITTINGS TRAP ARM MAY NOT CHANGE SIZE TRAP TO BE SAME SIZE AS TRAP ARM TRAP MAY BE ONLY ONE PIPE SIZE LARGER THAN TAILPIECE. |