Permit: T06CM04451

Parcel: 140553320

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/29/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/27/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) PATIO COLUMNS STILL NO PER PLAN
2) NO ACCESS
3) NO LADDER
09/22/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSUFFICIENT SHEAR NAILING AT BACK PATIO
2) GARAGE HDR REQUIRES 3 KING STUDS PER PLAN
3) SILL PLATE AT GARAGE DOOR OVERHANGING KEY WAY
4) FRONT BEDROOM WINDOW REQUIRES DBL 2 X 8 HDR
5) HDR MISSING AT ENTRY
6) SHEAR TRANSFER DETAIL 10/DT1 NOT COMPLIED WITH
7) HINGE BRACING NOT PER PLAN
8) PROVIDE POSITIVE CONENCTION FOR BACK PATIO
9) PROVIDE CITY APPROVED TRUSS SPECS
10) REPLACE DAMAGED ROOF SHEATHING
11) 8D NAILS 6" ON CENTER REQUIRED IN BIRD BLOCKS PER 6/DT-1
12) PATIO COLUMNS NOT PER PLAN
09/21/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CORRECTIONS FROM INSPECTION 9/20/06 HAVEN'T BEEN CORRECTED
2) NO GROUNDING BOND
3) NO STREET IDENTIFICATION
09/20/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS
2) EXTERIOR BOX COLUMNS NOT BUILT TO DRAWING 15/DT1
3) MISSING 2 X 6 JOIST HANGER BACK PORCH
4) N.W. GARAGE OPENING KING STUDS NEED TO BE ON FLOOR