Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM04450
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/27/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 12/26/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NO STREET ADDRESS ON HOUSE (REPEAT) 2) DRYER VENT STUCK CLOSED (REPEAT) 3) INCANDECENT LIGHT NOT ALLOWED WITHIN 12" HORIZONTALLY OF SHELF IN CLOSE CLOSET (REPEAT) 4) ATTIC ACCESS BLOCKED WITH WIRES MUST HAVE A 30" OBSTRUCTION FREE ACCESS (REPEAT) 5) NO LADDER ACCESS TO ATTIC FAU 6) 36" CLEARANCE REQUIRED BETWEEN STAIR BULL NOSE AND WALL 7) STOPPED INSPECTION |
|
| 12/13/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) REMOVE TILE FROM ROOF 2) NO STREET ADDRESS ON HOUSE 3) STUCCO NOT COMPLETE 4) DRYER VENT STUCK ON CLOSED 5) SECURE A/C WHIP 6) NO STAIR HANDRAILS 7) GARAGE MAN DOOR MUST SELF CLOSE/LATCH 8) HALL BATH GFI OBSTRUCTED BY MEDICINE CLOSET/CABINET 9) INCANDESCENT LIGHT NOT ALLOWED WITHIN 12" HORIZONTALLY OF MASTER BATH CLOSET SHELF 10) ATTIC ACCESS BLOCKED BY WIRES 11) FAU NOT COMPLETE IN ATTIC 12) 36" REQUIRED BETWEEN STAIR BULL NOSE AND WALL 13) STOPPED INSPECTION-TOO MANY ITEMS |