Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM04427

Parcel: 141314900

Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T06CM04427

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
10/12/2006 ROOF NAILING Approved IVRS - Inspection :*
10/09/2006 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL ALL STUDS ATTACHED TO H.D.'S TO SHEAR
2) ALL CMST STRAPS TO BE NAILED TO SOLID WOOD
3) DBL STUD UNDER 2ND FLOOR ROOF GIRDER
4) MORE NAILS IN FRIEZE BOARDS AT T.J.F.
5) IN GARAGE NAIL BOTTOMS OF SHEAR PANELS
6) END GABLES NOT TO BE NOTCHED MORE THAN 24" FROM HEEL JOINT