Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM04425
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) BLK AT PEAKS 2) PLYWOOD ALL 4 SIDES OF COLUMNS 3) VALLEY SHEATHING ROOF ? 4) WIND BRACE SOUTH SIDE NOT NAILED 5) REAR WALL MISSING 2ND/1ST FLOOR STRAPS 6) REAR WALL MISSING SHEAR NAILING 7) NEED DETAIL TJI TO ROOF SHEAR TRANSFER 14" DEPTH TOO DEEP TO BLK 8) CHECK ALL HORIZONTAL SHEAR NAILING 9) CORNER STUD N/W NOT NAILED TO T/PLATE 10) FINISH NAILING THA HANGERS AT ROOF BEAM 11) CMST STRAP PER PLAN IS 3" WIDE |