Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM04425

Parcel: 141315300

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04425

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/04/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/28/2006 EXT METAL CLIPS/EXT SHEATHING Denied 1) BLK AT PEAKS
2) PLYWOOD ALL 4 SIDES OF COLUMNS
3) VALLEY SHEATHING ROOF ?
4) WIND BRACE SOUTH SIDE NOT NAILED
5) REAR WALL MISSING 2ND/1ST FLOOR STRAPS
6) REAR WALL MISSING SHEAR NAILING
7) NEED DETAIL TJI TO ROOF SHEAR TRANSFER 14" DEPTH TOO DEEP TO BLK
8) CHECK ALL HORIZONTAL SHEAR NAILING
9) CORNER STUD N/W NOT NAILED TO T/PLATE
10) FINISH NAILING THA HANGERS AT ROOF BEAM
11) CMST STRAP PER PLAN IS 3" WIDE