Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T06CM04413
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/22/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
09/21/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 3" CI WASTE OK TO COVER INSTALL FD AND TRAP PRIMER, FOAM PIPE WRAPS AND RECALL ROUGH INSPECTION PRIOR TO CONCRETE. |
|
09/20/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PROVIDE APPROVED PLANS - COMPLETE VENT AT WC - POINT OF VENT AT MOP SINK IS BELOW WEIR OF TRAP, CONVENTIONAL VENTING REQUIRED. - 3" MAIN LINE IS OK TO BACKFILL REQUIRED THAT PLANS ARE ON SITE FOR NEXT INSPECTION APPROVED. |