Permit: T06CM04409

Parcel: 114600430

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM04409

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/18/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/24/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. OK TO COVER WALLS
2. CLOSET FLANGES OK
3. ICE MAKER INSTALLED IS NOT SHOWN ON YOUR PLAN
4. REDLINE ANY CHANGES MADE
5. ICE MAKER VALVES ARE QUICK CLOSING AND REQUIRE A HAMMER ARRESTOR.
6. ALSO, SOME ICE MAKERS REQUIRE BACKFLOW PROTECTION.
01/11/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. PROVIDE REDLINE FOR ICE MAKER IN BREAKROOM #108
2. TEST OK IN WALLS FOR RESTROOM #107 & BREAKROOM 108
3. WATER PIPING NOT INSTALLED IN RESTROOM #110
4. YARD WATER NOT ON ACTIVITY CARD
TEST ON YARDWATER OK