Permit: T06CM04395

Parcel: 10309068D

Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Permit Number - T06CM04395

Inspection Description - ENGINEERING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/08/2008 ENGINEERING - FINAL Approved
04/25/2008 ENGINEERING - FINAL Denied DENNIS W/CHESTNUT 275-0419

-REMOVE PORTA TOILETS
-REMOVE ROLL OFF DUMPSTER
-ASPHALT PATCH AT N DRIVEWAY WORK BEING DONE
-SIDEWALK RAMP AT SE CORNER DOES NOT COMPLY WITH ADA 4.8.2 + 4.8.4 (5.5" IN 4'= 11.4%)
-TRUNCATED DOMES ARE MISSING AT SW STRIPED SIDEWALK AND AT SE STRIPED SIDEWALK. THESE ARE NOT CALLED OUT AS EXISTING ON SITE OR GRADING PLAN
-RIP RAP WORK BEING DONE AT W LIMIT OF PROJECT
-ACCESS TO BASIN HAS BEEN BLOCKED BY CURBING
-PLZ RECALL AT BUILDING FINAL, COMPLETE ALL SITE WORK AND CALL IN FOR FINAL GRADING ON T06BU01750