Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 10/20/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio PLEASE PAY REINSPECTION FEE AT 201 N. STONE TAKE CARE OF ITEMS 1 & 2 NOTED ON 10/3/06 |
|
| 10/03/2006 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1. LEVEL LANDING REQUIRED @ EXTERIOR OF ACCESSIBLE RESTROOMS 2. SPLIT FRONT TOILET SEATS REQUIRED ON ALL TOILETS. 3. DEADBOLT ON ACCESSIBLE PATH (REAR DOOR OF TENANT SPACE) MUST BE NO HIGHER THAN 48" 4. DEADBOLT ON FRONT DOOR TO BE NO HIGHER THAN 48" OR PUT UP SIGN "THIS DOOR TO REMAIN UNLOCKED..." 5. GRAB BARS IN RESTROOMS TO BE INSTALLED PER ANSI 117.1 SECTION 604.5 |
|
| 09/25/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. POST ADDRESS DISPLAY PER P.C.Z.O 18.83.050 (ATTACHED SHEET) 2. DOUBLE BOWL SINK NOT SHOWN ON PLAN AND NOT INSTALLED PER CODE. A. YOU CAN'T HAVE 2 FIXTURES ON SAME TRAP ARM. B. YOU NEED TO VENT SINK TRAP ARM WITHIN 5' OF TRAP. YOU MAY USE AN A.A.V IN THIS APPLICATION. 3. WHEN WILL DELTA 1 REVISIONS (KEYNOTE 9, 10) BE IN PLACE? PLEASE PROVIDE APPROVED PLANS/PERMITS FOR ADA RESTROOMS. ADA RESTROOMS DO NOT MEET CHAPTER 11 REQUIRMENTS FOR ACCESSIBILITY. |