Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM04384

Parcel: 141315260

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04384

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/04/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/27/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NEED TJI BLKING (SHEAR TRANSFER)
2) PLAN CALLS FOR CMST STRAPS #7 ON HOLDOWN SCHEDULE CMST=3" WIDE, 54" LING
3) CS STRAPS ARE COIL STRAPS 1 1/4" WIDE
09/13/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) DETAIL LIVING TJI SHEAR TRANSFER DETAIL ON PLAN DOESN'T WORD APPROX 16" FROM ROOF TO DECK
2) ADD BLKS AT REAR ROOF GIRDER DOWN TO BEAM AND AT OTHER END OF GIRDER 2 NEED STUD AND BLK
3) QUES. CMST COIL-STRAP 3" WIDE, IS NOT COIL STRAP
09/11/2006 EXT METAL CLIPS/EXT SHEATHING Denied 1) MISSING TOO MANY ITEMS. LACKING SAME ITEMS AS LOT 111 AND 09