Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM04384
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED TJI BLKING (SHEAR TRANSFER) 2) PLAN CALLS FOR CMST STRAPS #7 ON HOLDOWN SCHEDULE CMST=3" WIDE, 54" LING 3) CS STRAPS ARE COIL STRAPS 1 1/4" WIDE |
|
| 09/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) DETAIL LIVING TJI SHEAR TRANSFER DETAIL ON PLAN DOESN'T WORD APPROX 16" FROM ROOF TO DECK 2) ADD BLKS AT REAR ROOF GIRDER DOWN TO BEAM AND AT OTHER END OF GIRDER 2 NEED STUD AND BLK 3) QUES. CMST COIL-STRAP 3" WIDE, IS NOT COIL STRAP |
|
| 09/11/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) MISSING TOO MANY ITEMS. LACKING SAME ITEMS AS LOT 111 AND 09 |