Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM04383
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) NEED DETAIL FOR TJI SHEAR TRANSFER IN LIVING ROOM 2) CMST 16 ISN'T A ? 3) STRAP 3" WIDE |
|
| 09/11/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) MISSING STRAP AT SHEAR CORNER 1ST/2ND FLOOR REAR 2) NEED 1ST/2ND FLOOR STRAPS PERIMETER 3) CLIP SHEAR TO TRUSS AT TOP USING TABLE ON 10/DT1 4) NAIL OFF ALL WIND BRACES 5) TIE GARAGE END TRUSS TO BEAM 6) AT SHED ROOF T.J.I. NEED CONNECT FRIEZE BLK TO SOLID BLK 7) ADD BLKS VERT BEARING NEXT TO BEAM SUPPORT FOR GIRDER 2ND FLOOR 8) VERIFY HANGER NAILS 9) FLOOR TO FLOOR GIRDER SUPPORT REAR WALL ABOVE BEAM 2/2 X 4'S 10) 2ND FLOOR BOTTOM PLATES 6" ON CENTER SHEAR 12" ON CENTER NON SHEAR 11) BOND ? AND NAIL THA HANGERS 12) 4/DT2 PLYWOOD DOWN TO BOTTOM OF BEAM |