Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - LCBU - Masonry Pregrout
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - LCBU - Masonry Pregrout | Not Ready | ||
| 02/10/2022 | COT - LCBU - Masonry Pregrout | Partial Pass | {Activity date: 02/10/2022; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Partial, 2nd lift (8’) and bond beam/ steel lintels over doors at the wall separating sanctuary and lobby } ; {Activity date: 08/18/2021; Status: Partial Approval; Inspector: TGAUSP; Comment: Entered by VVERA1 - Partial, 1st lift for the wall separating sanctuary and lobby} ; {Activity date: 02/28/2020; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- Stem wall at electric room okay for grout } ; {Activity date: 10/07/2016; Status: Not ready for Inspection; Inspector: RCAMACHO; Comment: Entered by RCAMACHO - } ; {Activity date: 08/20/2015; Status: Partial Approval; Inspector: RCAMACHO; Comment: Entered by CSHARRA1 - RETAINING WALL AT EAST AND WEST EXTERIORS PER DETAIL C1/A5.6} ; {Activity date: 08/20/2015; Status: Partial Approval; Inspector: RCAMACHO; Comment: Entered by RCAMACHO - IVRS - Inspection :*} ; {Activity date: 10/22/2014; Status: Partial Approval; Inspector: RCAMACHO; Comment: Entered by ARUIZ1 - REINSPECTION OF 4 ENTRY COLUMNS DUE TO VANDALISM PER DETAILS 13, 11 & 14 /53.2} ; {Activity date: 10/22/2014; Status: Partial Approval; Inspector: RCAMACHO; Comment: Entered by RCAMACHO - IVRS - Inspection :*} ; {Activity date: 10/21/2014; Status: Not ready for Inspection; Inspector: RCAMACHO; Comment: Entered by RCAMACHO - IVRS - Inspection :*} ; {Activity date: 06/28/2011; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) 8 STEEL PLATES 3/4" X 2' ANCHOR BOLTS OK} ; {Activity date: 12/07/2010; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) NEED TO SEE PLATES WITH 3/4" X 2' ANCHORS} ; {Activity date: 06/17/2010; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :*} ; {Activity date: 11/05/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) PASTORS OFFICE TOP OUT OK WITH COMPLAINT SPECIAL INSPECTION } ; {Activity date: 11/04/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) WEST ARCHS TOP 2) PASTORS OFFICE EAST AND WEST WALL TOP OUT NORTH WALL 3RD LIFT 3) REQ SPECIAL INSPECTION} ; {Activity date: 11/02/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) REMAINING PASTORS OFFICE TO 8' WEST PART OF WEST ARCHES TOP OUT} ; {Activity date: 10/30/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) REMAINING 4 ARCHES ON WEST SIDE TO LINTELS 2) PASTORS OFFICE ALL BUT BETWEEN WEST WINDOW AND DOOR 3) SPEEDIE INSPECTED} ; {Activity date: 10/29/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) WORKING ON WEST SIDE LAST 4 ARCHES AND 2ND LIFT PASTOR OFFICES-WILL RECALL} ; {Activity date: 10/28/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) EAST SIDE ARCHES TOP OUT OK 2) PASTORS OFFICE 1ST LIFT POUR AT OWN RISK, CONFLICTING DETAIL VERSES KEY NOTE. DONE PER KEY NOTE} ; {Activity date: 10/26/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* REMAINING ARCHES ON EAST SIDE TO LINTELS} ; {Activity date: 10/23/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* WEST SIDE ARCHES 6&7 TOPOUT} ; {Activity date: 10/22/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) WEST SIDE, ARCHS 6 & 7 FROM SOUTH SIDE TO LINTER HEIGHT 2) NEED SPECIAL INSPECTION 3) MAINTAIN REBAR CLEARANCE FOR COVERAGE} ; {Activity date: 10/20/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) WEST SIDE ARCH 4F5 TOP OUT 2) EAST SIDE ARCH 6 + 7 TOP OUT 3) SPECIAL INSPECTED} ; {Activity date: 10/19/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) WEST SIDE ARCH 4 & 5 TO LINTELS 2) TOP OF WALL ABOVE ARCH 1, 2 & 3 3) COLUMN 8 TO 4'} ; {Activity date: 10/16/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) EAST SIDE ARCHS COLUMNS 5 +6 TO 12' AND COLUMN 8 TO 4' 2) WEST SIDE 1,2 AND 3 ARCHS TO 12' 3) SPEEDIE SPECIAL INSPECTED} ; {Activity date: 10/15/2009; Status: Not ready for Inspection; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) EXTERIOR WALLS NEED TO BE BRACED UNTIL ROOF SYSTEM INSTALLED OR PROVIDE ENGINEERED ALTERNATIVE} ; {Activity date: 09/11/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) 5 + 6 ARCHWAY TO LINTELS FROM SOUTHEAST CORNER 2) KEEP GROUT DOWN 1/2" TO 2" FOR KEY WAY ON NEXT LIFT} ; {Activity date: 09/09/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 5 ARCHES SE CORNER TOP OUT OK WITH SPECIAL} ; {Activity date: 09/03/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 5 MASONRY ARCHES SE CORNER TO BELOW MASONRY LINTELS LINTELS TO BE POURED IN ONE POUR} ; {Activity date: 07/29/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) NW, SW, SE MASONRY COLUMNS AT BLDG FIRST LIFT OK} ; {Activity date: 07/24/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) 9 COLUMN EAST 9 COLUMNS WEAT TO 8' BOTTOM OF ARCHES 2) PROVIDE 2 #5 BOTTOM OF ARCH EACH CELL 3) PROVIDE SPECIAL INSPECTION 4) NEED REVISED PLANS ON SITE} ; {Activity date: 07/22/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) 1ST LIFT 9 WEST COLUMN 5 2) TO BE SPECIAL INSPECTED} ; {Activity date: 07/15/2009; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* 1) 1ST LIFT 9 EAST COLUMNS 2) PROVIDE SPECIAL INSPECTION} ; {Activity date: 10/31/2008; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* BLDG. TOP OUT OK} ; {Activity date: 10/29/2008; Status: Partial Approval; Inspector: LHANLY; Comment: Entered by LHANLY - IVRS - Inspection :* TOP OUT MAIN BLD. OK (SOUTH WALL COMPLETE)} ; {Activity date: 10/23/2008; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* ABOVE SOUTH STEEL LINTEL TO 2 COURSES SHORT OF TOP OUT OF REMAINING BLDG. S3.3 (4)/S3.2 (6) } ; {Activity date: 10/21/2008; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* SO MASONRY LINTEL ABOVE LT1 STEEL LINTEL TO 30" ABOVE STEEL OK TO GROUT WITH SPECIAL INSPECTION} ; {Activity date: 09/24/2008; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* SOUTH WALL FROM WEST CORNER TO 2ND CONTROL JOINT OK TO TOPOUT TO BE SPECIAL INSPECTED} ; {Activity date: 09/23/2008; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* SOUTH WALL FROM WEST CORNER TO 2ND CONTROL JOINT 2'8" FROM TOP OUT OK TO GROUT} ; {Activity date: 09/22/2008; Status: Partial Approval; Inspector: MHENSON; Comment: Entered by MHENSON - IVRS - Inspection :* EAST 1/2 OF SOUTH WALL FROM CORNER TO 2ND CONTROL JOINT TOP OUT} ; {Activity date: 09/15/2008; Status: Partial Approval; Inspector: GDABBS; C |