Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T06CM04364
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/06/2007 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO FINISH SHEET ROCK |
|
02/21/2007 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* NO CLEARANCE AT UPPER ROOF |
|
02/07/2007 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK TO SHEETROCK EVERYTHING EXCEPT WATER HEATER ROOM |
|
02/05/2007 | MECHANICAL - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
01/18/2007 | MECHANICAL - INTERMEDIATE | Continued | COURTESY INSPECTION 1. 1/2" GAS PIPING NOT PER PLAN. PLAN REQUIRES 3/4" TO FURNACE. ALSO, REQUIRES A ROOF PENETRATION. 2. EXTEND FLUE VENTS 2' ABOVE COMBUSTION AIR INTAKES 3. PLANS REQUIRE COPPER. PVC WAS INSTALLED 4. PLANS REQUIRE SERVICE RECEPTACLES AT EACH UNIT. 5. PROVIDE SCREENS IN ALL T-TOPS EXCEPT DRYER VENT. 6. SECURE CONDENSATE DRAIN TO WALL, PROVIDE AN ELBOW AND NIPPLE AT BOTTOM & DIVERT WATER AWAY FROM HOUSE. PROGRESS INSPECTION FOR WORK TO BE COMPLETED BY CURRENT CONTRACTOR. |