Permit: T06CM04364

Parcel: 11615194B

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T06CM04364

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/06/2007 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
OK TO FINISH SHEET ROCK
02/21/2007 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
NO CLEARANCE AT UPPER ROOF
02/07/2007 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK TO SHEETROCK EVERYTHING EXCEPT WATER HEATER ROOM
02/05/2007 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/18/2007 MECHANICAL - INTERMEDIATE Continued COURTESY INSPECTION
1. 1/2" GAS PIPING NOT PER PLAN. PLAN REQUIRES 3/4" TO FURNACE. ALSO, REQUIRES A ROOF PENETRATION.
2. EXTEND FLUE VENTS 2' ABOVE COMBUSTION AIR INTAKES
3. PLANS REQUIRE COPPER. PVC WAS INSTALLED
4. PLANS REQUIRE SERVICE RECEPTACLES AT EACH UNIT.
5. PROVIDE SCREENS IN ALL T-TOPS EXCEPT DRYER VENT.
6. SECURE CONDENSATE DRAIN TO WALL, PROVIDE AN ELBOW AND NIPPLE AT BOTTOM & DIVERT WATER AWAY FROM HOUSE.

PROGRESS INSPECTION FOR WORK TO BE COMPLETED BY CURRENT CONTRACTOR.