Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
Permit Number - T06CM04357
Inspection Description - PLUMBING - FINAL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/28/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE SEDIMENT TRAP AT FURNACE & WATER HEATER 2. PROVIDE ELECTRICAL BONDING (GROUND WIRE) 3. TERMINATE WATER HEATER T&P 6" TO 24" ABOVE GRADE 4. PROVIDE AIR PRESSURE TEST ON ALL GAS PIPING 5. PROVIDE AGA VALVES AND FLEXES LIST MAY NOT BE COMPLETE |