Permit: T06CM04351

Parcel: 141313610

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM04351

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/16/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/13/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) FINISH NAILING ALL SHEAR, MAINLY AT BOTTOMS OF SHEETS EXTERIOR & INTERIOR
2) NAIL ALL LEDGERS TO STUD LAYOUT KITCHEN/DINING ROOM
3) NAIL 2ND PLATES 12" ON CENTER 16D
4) ANSWER TO HEADER SIZE AT LIVING ROOM HEADER ABOVE LARGER 2ND, THAN 1ST FLOOR
5) WRONG HANTER AT HIIG DBL TRUSS NEED 1499 POUND CAPABILITY MIN.
11/08/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE H-TRUSSES WHAT HANGER IS TO BE USED
2) (505 LBS H-2) (H 11-G 1499)
3) GARAGE ADD A3.5 EVERY OTHER TRUSS TO PLAN ON LEDGER
4) USE .148 DIAMETER NAILS MIN AT GARAGE SHEAR
5) FRONT LIVING CANTILIEVER NOT PER PLAN, NEED TRUSS DRAWING OF TRUSS INSTALLED
6) PLEASE WALK HOUSE AND RECALL
7) NAIL ALL ROOF EDGES TO LEDGERS
8) LOOSE PLATE FRONT DOOR
9) TOO MANY ITEMS