Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2006 | PLUMBING - FINAL | Approved | PER INSP COPY | |
| 11/15/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. DRAINAGE PIPING TO HAVE A SMOOTH INTERIOR WATERWAY. EWC TO HAVE A TRAP 1 1/4" C.P 17 GAUGE P-TRAP |
|
| 11/14/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* REMOVE COVER AT EWC |
|
| 10/30/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. INSTALL COUNTER SUNK TAPPED CLEANOUT PLUG AND USE A C.P COVER PLATE (SEE NOTE#1 ABOVE) 2. ELECTRIC WATER COOLER DRAIN NOT APPROVED. (SEE NOTE #2 ABOVE) |
|
| 09/15/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. REMOVE FOAM FROM AROUND CLEANOUT. INSTALL COUNTER SUNK TAPPED CLEAN-OUT PLUG AND USE A COVER PLATE. 2. ELECTRIC WATER COOLER DRAIN NOT PER CODE. POINT OF VENT MAY NOT BE BELOW TRAP WEIR. 3. SOME ADA REQUIREMENTS MAY INCLUDE INSULATING LAVATORY TAILPIECE AND TRAP FLUSH HANDLE ON WIDE SIDE 4. INSTALL VACUUM BREAKERS ON HOSE BIBBS. |