Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM04312
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED PORCH TRUSS PROBLEM RESOLVED-TRUSS DRAWINGS NOT CORRECT 2) NEED PORCH BEAM SIZE ON PLAN 3) 9 1/8 X 3 1/8 PORCH GLU LAMS ARE NOTCHED AT ? 4) G-3 BLKD SHEAR ON SOUTHWEST END TOO BE 4'-0" ON CENTER 5) NAIL SHEAR BLOCKING PANELS TO ROOF 6) CHECK RAT RUNS WITH REVISED T-DRAWINGS 7) OVER FRAMING AT 4' ON CENTER |