Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM04311
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/28/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H.D. NOT BOLTED AT GARAGE 2) SOFFIT LOWER AT KITCHEN NEED F1 BLKS 3) MISSING SHEAR TRANSFER GARAGE TO HOUSE WALL SOUTH END 4) #3 & #4 BELOW NOT DONE |
|
| 12/22/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/15/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) AB'S AT 24" ON CENTER GARAGE NORTH 2) BLOCK ALL MECH 3) BANG PLATE 3" DRAIN FURNACE ALCOVE GARAGE 4) DRYWALL BACKING FURNACE DUCT LID 5) TWO MANY H.D. PLANS, NEED A CLEAR H.D. PAGE OFR 3 CAR GARAGE, ON THE SHEAR PAGE S1.2 CONCRETE PAGE SHOWS H.D.'S PAGE BUT NOT SHEARWALL TYPE 6) BANG PLATE 3" ABS KITCHEN CLOSET H.D. 7) REPAIR SHEAR CORRECTLY LIVING ROOM 8) DIVERTER STUD OVER NOTCHED 2ND FLOOR BATH 9) 2ND FLOOR SHEAR PLATES 12" ON CENTER ? SINKERS 10) BLOCK 2ND FLOOR FURNACE DUCT AT ? 11) FINISH LATHE AT FRONT 12) UFER CUT |