Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM04311
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REAR 2ND FLOOR TRUSS REQUIRES CONTINOUS BEARING 2) 2ND FLOOR INTER. SHEAR NEEDED IN CLOSET 3) INSTALL POST GARAGE 4) LOOSE SHEAR 2ND REAR 5) MISSING WIND BRACE S. SIDE |
|
| 11/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLAN NOT SPECIFYING HANGERS (TYPE/SIZE) 2) SHEARWALL AT KIT DROP, SHEATHWALL OR INSTALL TRANSFER TO SHEETROCK 3) LEDGER NOT CLIPPED A3.5 EVERY OTHER TRUSS GARAGE 4) CANT. BEAM INSTALLED AT LIVING ROOM NOT ON PLAN 5) TRUSS DRAWING FOR THAT END TRUSS NOT IN TRUSS BOOK 6) END TRUSSES THAT REQUIRE CONTINOUS BEARING TO BE SHIMMED 7) ALL 1/2 TRUSS IN LIVING ROOM ARE TO BEAR AT TOP CHORD 8) RAT RUNS DG21 TRUSS |