| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/19/2006 | FRAMING | Partial Approval | IVRS - Inspection :* MISSING A-B HD AT GARAGE NEED 3 CAR SHEAR |
|
| 12/13/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REAR SCUPPERS NOT DONE 2) DUCT NOT ATTACHED (MAKE UP AIR AT FURN) 3) NAIL ALL STUDS GARAGE SHEAR 4) NEED HEADER AT KITCHEN VENT 5) 8D IN 3" DRAIN GARAGE, SECURE 3" DRAIN IN WALL 6) STRAP DRYER DUCT AT T/PLT 7) LEAK IN 3" DRAIN KITCHEN/DINING 8) STIFF LEG 1ST FLOOR BATH FLAT 2 X 4 LID 9) SHIM ALL LET INS 10) H.D.'S AT 3 GARAGE SHEAR |